![]() System : Linux absol.cf 5.4.0-198-generic #218-Ubuntu SMP Fri Sep 27 20:18:53 UTC 2024 x86_64 User : www-data ( 33) PHP Version : 7.4.33 Disable Function : pcntl_alarm,pcntl_fork,pcntl_waitpid,pcntl_wait,pcntl_wifexited,pcntl_wifstopped,pcntl_wifsignaled,pcntl_wifcontinued,pcntl_wexitstatus,pcntl_wtermsig,pcntl_wstopsig,pcntl_signal,pcntl_signal_get_handler,pcntl_signal_dispatch,pcntl_get_last_error,pcntl_strerror,pcntl_sigprocmask,pcntl_sigwaitinfo,pcntl_sigtimedwait,pcntl_exec,pcntl_getpriority,pcntl_setpriority,pcntl_async_signals,pcntl_unshare, Directory : /usr/share/doc/python-libxml2/examples/ |
Upload File : |
#!/usr/bin/python -u # -*- coding: ISO-8859-1 -*- # # this tests the next API of the XmlTextReader interface # import libxml2 import sys try: import StringIO str_io = StringIO.StringIO except: import io str_io = io.StringIO # Memory debug specific libxml2.debugMemory(1) f = str_io("""<a><b><c /></b><d>content of d</d></a>""") input = libxml2.inputBuffer(f) reader = input.newTextReader("test_next") ret = reader.Read() if ret != 1: print("test_next: Error reading to first element") sys.exit(1) if reader.Name() != "a" or reader.IsEmptyElement() != 0 or \ reader.NodeType() != 1 or reader.HasAttributes() != 0: print("test_next: Error reading the first element") sys.exit(1) ret = reader.Read() if ret != 1: print("test_next: Error reading to second element") sys.exit(1) if reader.Name() != "b" or reader.IsEmptyElement() != 0 or \ reader.NodeType() != 1 or reader.HasAttributes() != 0: print("test_next: Error reading the second element") sys.exit(1) ret = reader.Read() if ret != 1: print("test_next: Error reading to third element") sys.exit(1) if reader.Name() != "c" or reader.NodeType() != 1 or \ reader.HasAttributes() != 0: print("test_next: Error reading the third element") sys.exit(1) ret = reader.Read() if ret != 1: print("test_next: Error reading to end of third element") sys.exit(1) if reader.Name() != "b" or reader.NodeType() != 15: print("test_next: Error reading to end of second element") sys.exit(1) ret = reader.Next() if ret != 1: print("test_next: Error moving to third element") sys.exit(1) if reader.Name() != "d" or reader.IsEmptyElement() != 0 or \ reader.NodeType() != 1 or reader.HasAttributes() != 0: print("test_next: Error reading third element") sys.exit(1) ret = reader.Next() if ret != 1: print("test_next: Error reading to end of first element") sys.exit(1) if reader.Name() != "a" or reader.IsEmptyElement() != 0 or \ reader.NodeType() != 15 or reader.HasAttributes() != 0: print("test_next: Error reading the end of first element") sys.exit(1) ret = reader.Read() if ret != 0: print("test_next: Error reading to end of document") sys.exit(1) # # cleanup for memory allocation counting # del f del input del reader # Memory debug specific libxml2.cleanupParser() if libxml2.debugMemory(1) == 0: print("OK") else: print("Memory leak %d bytes" % (libxml2.debugMemory(1))) libxml2.dumpMemory()